Medium Range
Remote Digital
1 Channel Wireless Control
System NEMA 3R
•
2000. feet ( 600.m)
in-building range •
2
Miles (3.Km)
open-air range
• 6
miles ( 10 km) line-of-sight with
Long Range Antenna
Weather-Resistant Case, Accepts N/O or N/C Inputs, Complete RF Supervision, Field Enabled
Transmitter
| |
SPECIFICATIONS
Operating Frequency: 27.255
MHz Number of Codes: 65,536,
Digital 16 Bit Code
Setting: DIP switch programming Operating Voltage: 12 VDC (power source not supplied) Operating Current: Standby
- 15 µA,
transmitting 2.0 Amps at 12 VDC
Antenna Impedance: 50 Ohms Optional Temperature Range: -20º to +60º C
(-4º to +140º F) Dimensions:
9.5 in
L x 5.5 in W x 4 in D (240 x 140 x 92 mm)
Weight: 4.2 lb. (2.2 Kg)
Operating Temperature: -4°
to +140° F (-20° to +60° C) RF
Output Power: 12 Watts
typical
Loop
Response Time: 500 msec Code Transmissions: Alarm, restore,
status, and low battery Transmit Time: 1 second
Unlimited
application,
Control, Monitoring,
Security |
|
Receiver
| |
SPECIFICATIONS
Operating
Frequency: 27,255 MHz
Number of Codes: 65,536,
Digital 16 Bit
Code Setting: DIP switch programming
Operating Voltage: 12 VDC (power source not supplied)
Data Input: Alarm, restore,
status, and low battery Antenna Impedance: 50 Ohms
Optional
Dimensions: 9.5 in
L x 5.5 in W x 4 in D (240 x 140 x 92 mm)
Weight: 4.2 lb. (2.2 Kg)
Operating Temperature: -4°
to +140° F (-20° to +60° C) Current Drain: 30mA, typical
standby 70 mA alarm @ 12 VDC Outputs: Alarm - form "C" relay per channel
Status exception -
one open collector output per receiver;
Low Battery - one open collector output per receiver
The Low battery and status outputs are solid state
switching
up to 50 mA @ 20 VDC to ground
Output provides isolated N/0 and N/C
relay contacts
capable of switching a maximum of 1 Amp @ 32 VDC.
Optional output relays: Power Relay
Latch Relay
|
|
|
|